Why mobee med®?
Precise NECK, SPINE & JOINT range of motion
You can follow the execution of the movement in real time on-screen and mark relevant additional information "at the click of a button", such as a pain arc and joint end feel. The results are presented in a clear and appropriate way (with built-in expert / patient modes). To assist the professional in the evaluation and reporting (e.g. for third-party reports), we have included automatic comparisons of patient measures to built-in reference values (which may be edited by the professional for special populations). Active versus Passive ROM and right versus left comparisons are provided. Progressive numerical and chart displays over time underline the success of the therapy.
The analysis is carried out with the aid of a compact, 3 sensor-based TGA Class I medical measuring device, which also serves to comfortably control the software. With incredible German precision - the device technical error margin is less than 1 degree!.
mobee med® is excellently suited in combination with mobee fit® for the workplace health promotion.
mobee med® is excellently suited in combination with mobee fit® for the workplace health promotion.
- Precise, digital assessments for the eHealth era
- Increase motivation and patient compliance
- Referral and recommendation opportunities in your network
- Instant reports, showing measured improvements over time with treatment
mobee med® supports you in MEASURING neck, spine and peripheral joint mobility. As a digital companion, the system helps you to direct mobility therapy and makes even small successes visible. As a clinician, you benefit from standardised procedures and efficient documentation. Standard goniometry was yesterday - mobee med® is today!

Video can’t be displayed
This video is not available.
We are currently working on the translation of these demonstration videos into English. Thank you for your patience.
Analysis options include :
-Cervical spine-Thoracic and lumbar spine-Shoulder-Elbow-Wrist-Hip
-Knee-Ankle-Active & Passive-Upright and horizontal multiple testing positions position
Demonstration of the ZERO NEUTRAL METHOD - for mobee med® - and how this advanced technology can assist the clinician when the zero position to begin goniometric measurement is not practical due to the patient's condition.

Video can’t be displayed
This video is not available.
THE BENEFITS - FOR BUSY CLINICIANS - IN DETAIL
mobee med® is an advanced German designed and manufactured digital goniometer with accompanying English software. It assists clinicians performing a patient physical examination with accurate assessment and instant reporting of joint Range of Motion, in the 3-planes. It is now available in Australia and is a TGA registered Class 1 Medical Measurement Device.
HOW DOES mobee med® WORK?
This wireless and compact measurement device is placed on the relevant joints or body regions during the patient's physical examination. Then, a predefined joint motion is carried out in accordance with goniometric principles of the neutral-zero-method. The measured values are transferred to a laptop/pc via radio transmission and displayed on-screen in real time. Afterwards, results are saved for evaluation purposes and follow-up.
THE MEASUREMENT PROCESS
mobee med® guides you through the entire measurement process step-by-step. The sensitive 3-sensor technology allows for incredible measuring accuracy. It is also time efficient for clinicians with instant reporting of measured angles. The software automatically makes comparisons of the patient's measurements to built-in normative ranges (sourced from a review of the evidence-base by our partner IPN - the leading German Institute for Prevention & Aftercare), and to the patient's own previous measurements. These normative range values can also be modified by the clinician in the software.
mobee med® enables almost all standard goniometric measurement procedures – whether in standing, lying or in sitting position. Rotational movements in the transverse plane have often been more difficult for clinicians to measure and manually record with standard goniometers or with less reliable visual estimation. Often there is a demand for the use of auxiliary constructions, accessory devices or even making it necessary to reposition the patient. Now all you need is one instrument to ensure a highly precise examination of joint mobility.
mobee med® economises handwritten documentation. All measurements are automatically saved, including a comprehensive and descriptive illustration of the measurement results. The software instantly generates reports of findings for the busy clinician!
mobee med® offers unparalleled assessment, which assists you in comparing measurement results between examinations, e.g. pre-post treatment, in order to obtain evidence of success which is based on objective results. Graphic-based comparison of active and passive measurements to the other extremity as well as to reference sources is also possible.
mobee med® delivers helpful additional information, like degree of pain or end feeling, and can even record pain arcs, e.g. during shoulder abduction. You can directly document these entries using your measurement device. The unique option “pain marker“, allows you to precisely locate pain areas.
SPECIAL FEATURES
COMPREHENSIVE MEASUREMENT CATALOGUE
With more than 100 measurement types, mobee med® offers a wide range of measuring possibilities for physical examination.
Thanks to different positions (sedentary, upright, recumbent) it is possible to find the best option for every objective.
Thanks to different positions (sedentary, upright, recumbent) it is possible to find the best option for every objective.
USER FRIENDLY OPERATION
The initial teach-in allows clinicians to perform measurements intuitively even if they have limited experience in range of motion assessment. The simultaneous display of the measurement process on-screen allows for an ideal overview during the whole measurement process.
Thanks to the wireless operation of the software via the measuring device, the clinician can focus on the patient rather than on the technical device.
Thanks to the wireless operation of the software via the measuring device, the clinician can focus on the patient rather than on the technical device.
ADD USER OWN PROFILES
Due to intuitive filter and drag & drop functions, mobee med® allows a time-saving creation for the clinician's own examination sequence.
Thus, it is possible to permanently save your favourite examination combinations in order to access them quickly for next time.
Thus, it is possible to permanently save your favourite examination combinations in order to access them quickly for next time.
NEUTRAL-ZERO-POSITION IMPOSSIBLE

Video can’t be displayed
This video is not available.
Neutral-Zero-Position impossible
If it is not possible to reach the pre-defined starting position for an examination due to the patient's condition (as seen here in an impingement syndrome), this deficit will be calculated and documented by the mobee med® system. Two options built in to the system will either automatically detect the starting position from true zero, or allow the practitioner to position the sensor at true zero and then calculate from the actual examination starting position.
If it is not possible to reach the pre-defined starting position for an examination due to the patient's condition (as seen here in an impingement syndrome), this deficit will be calculated and documented by the mobee med® system. Two options built in to the system will either automatically detect the starting position from true zero, or allow the practitioner to position the sensor at true zero and then calculate from the actual examination starting position.
OPTIONS FOR ATTACHMENT
The mobee med® measuring device can be attached to the elastic fastening belts included in the delivery by using the special belt clips. Particularly when performing active measurement types (i.e. the patient actively performs the motion him- or herself), we recommend that the measuring device be securely positioned.
DOCUMENTATION OF PAIN AND END-FEELING
It is possible to directly register pain arcs as well as their intensity during the measurement. The clinician can also document certain characteristcs of the end feeling during this process.
With the help of these additional documentation features, pain improvement becomes visible even in cases where total mobility remains unchanged.
With the help of these additional documentation features, pain improvement becomes visible even in cases where total mobility remains unchanged.
STATUS REPORT FOR A QUICK OVERVIEW
The first step of the evaluation is a compact status report, which clearly summarizes the relevant information.
The status report displays all gathered measurement data and can be a basis for the following diagnosis. Several graphical diagrams are available for detailed evaluation.
The status report displays all gathered measurement data and can be a basis for the following diagnosis. Several graphical diagrams are available for detailed evaluation.
COMPARISON
The evaluation also includes a comparison to scientifically acknowledged reference values. Alternatively, it is possible for the clinician to add their own individual reference values.
This comparison is an effective way to further classify the achieved measurement results.
This comparison is an effective way to further classify the achieved measurement results.
SPACE-SAVING
All components of the measuring system can be stored in a compact transport case. Thus, it is possible to transport and store the system comfortably using very little space. No additional space is required to perform examinations.